SciELO - Scientific Electronic Library Online

 
vol.41 número1A Bootstrapping Method for Improving the Classification Performance of the P300 SpellerCriterios Ergonómicos para el Diseño de Quirófanos índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Revista mexicana de ingeniería biomédica

versión On-line ISSN 2395-9126versión impresa ISSN 0188-9532

Resumen

ACOSTA-SANCHEZ, L. A.; BOTELLO-ARREDONDO, A. I.; MOYA-BENCOMO, M. D.  y  ZUNIGA-AGUILAR, E. S.. Porous Lattice Structure of Femoral Stem for Total Hip Arthroplasty. Rev. mex. ing. bioméd [online]. 2020, vol.41, n.1, pp.69-79.  Epub 23-Oct-2020. ISSN 2395-9126.  https://doi.org/10.17488/rmib.41.1.5.

Total Hip Arthroplasty (THA) is one of the surgical procedures carried out satisfactorily in procedures for osteoarthritis and trauma lesions. ATC surgery reduces pain and improves the quality of life of young patients. Therefore, it is of great importance to improve the properties of hip implants, since current implants do not match their lifespan with the life expectancy of a young patient. This is because the solid prostheses that currently exist have a higher Young's modulus, and therefore are too rigid compared to the bone tissue. On the other hand, the cyclic and continuous loads to which the hip joint is subjected in daily activities, can cause loosening and consequent implant loss The present work proposes an implant manufactured with a porous lattice structure, which aims to reduce stiffness, allow bone growth and a more effective mechanical load transfer. Three computational models subjected to static charges were evaluated and compared: 1) healthy femur, 2) implanted femur with a commercial prosthesis, and 3) implanted femur with a prosthesis with lattice structure. For the computational analysis it was decided to perform a static analysis of a person standing on the left foot; a load equivalent to the body weight was applied on the head of the femur, balancing the reaction forces in the system of forces (contact force, body weight, and abductor muscle).. The results were shown in terms of displacement, compression and deformation. The model implanted with a prosthesis with a lattice design presented a slight decrease in displacement, and a decrease in compression and deformation values, which indicated that the proposed design has a better distribution and transport of the loads through its structure.

Palabras llave : Total Hip Arthroplasty; Hip Implant; Femoral Stem; Orthopaedics; Lattice; Finite Element Analysis.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )