SciELO - Scientific Electronic Library Online

 
vol.67 número6Predictive study of ferromagnetism and antiferromagnetism coexistence in Ba1-xGdxRuO3 induced by Gd-dopingFrom chaos to stability in soliton mode-locked fiber laser system índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Revista mexicana de física

versión impresa ISSN 0035-001X

Resumen

QUEREBALU GARCIA, C.; CARRASCO SOLIS, E.; VALLADOLID SALAZAR, J.  y  CENTENO RAMOS, J.. Evaluation of the impact of parameters on the gamma index for breast cancer treatments. Rev. mex. fis. [online]. 2021, vol.67, n.6, 061101.  Epub 14-Mar-2022. ISSN 0035-001X.  https://doi.org/10.31349/revmexfis.67.061101.

Volumetric modulated arc radiotherapy treatments (VMAT) can achieve highly conformed dose distributions however, due to the complexity of the technique, there may have differences between the planned and administered dose distributions, generated by the precision in the dose calculation of the treatment planning system (TPS) or by the errors associated with it. One way to quantify the difference between both dose distributions is by using the gamma index; however, there is no accord regarding the parameters that should be used in its analysis. On the other hand, this gamma index may depend on the pathology and the area to be treated. For this reason, the present work aims to evaluate different parameters of the analysis of the gamma index for breast cancer treatments; these are local and global normalization, the analysis criteria (1%/1 mm, 2%/2 mm, 3%/2 mm, 2%/3 mm, 3%/3 mm and 5%/3 mm), and the low dose threshold (LDT) of 5% and 10%. For this, 30 treatment plans performed with VMAT technique in a 6 MV Infinity linear accelerator (Elekta, Stockholm, Sweden) were analyzed, calculated with the TPS Monaco V.5.11.03 (Elekta, Stockholm, Sweden) and measured with the Octavius 4D system (PTW, Freiburg, Germany). The results of the analysis of the global gamma index were of a gamma passing rate (%GP) greater than 95% for analysis criteria of 3%/3 mm and 5%/3 mm; however, for these same parameters in the local gamma index analysis, the results are 85.8% and 91.1% respectively. In addition, from the LDT evaluation, it is observed that there is a mean increase of %GP for the local gamma index analysis and a mean decrease of %GP for the global gamma index analysis, for the LDT from 5% to 10%. On the other hand, the standard deviation is lower in the global gamma index; analysis than in the local one, and it decreases when the analysis criteria are less strict. It is concluded that there is not a great difference in choosing the LDT of 5% or 10%. When the gamma analysis criteria are less strict, the %GP increases both for the analysis of the local and global gamma index, taking this into account, each parameter should be used carefully according to the treatment plan to be analyzed, taking into account the advantages and disadvantages of each parameter.

Palabras llave : Gamma index; VMAT; lower dose threshold; analysis criteria; patient specific quality control.

        · texto en Inglés     · Inglés ( pdf )