SciELO - Scientific Electronic Library Online

 
vol.59 número4On the mass flow rate from silos with lateral exit holesCollinear inelastic collisions of an atom and a diatomic molecule using operator methods índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Revista mexicana de física

versión impresa ISSN 0035-001X

Resumen

FIGUEROA, R.G.; LOZANO, E.  y  BONGIOVANNI, G.. Element distribution imaging in rat kidney using a 2D rapid scan EDXRF device. Rev. mex. fis. [online]. 2013, vol.59, n.4, pp.292-295. ISSN 0035-001X.

Visualization of elemental distributions of biological tissue is gaining importance in many disciplines of biological, forensic, and medical research. Furthermore, the maps of elements have wide application in archeology for the understanding of the pigments, modes of preservation and environmental context. Since major advances in relation to collimators and detectors have yielded micro scale images, the chemical mapping via synchrotron scanning micro-X-ray fluorescence spectrometry (SR-µXRF) is widely used as microanalytical techniques. However, the acquisition time is a limitation of current SR-µXRF imaging protocols, doing tedious micro analysis of samples of more than 1 cm and very difficult to study of larger samples such as animal organ, whole organisms, work of art, etc. Recently we have developed a robotic system to image the chemistry of large specimens rapidly at concentration levels of parts per million. Multiple images of distribution of elements can be obtained on surfaces of 100x100 mm and a spatial resolution of up to 0.2 mm2 per pixel, with a spectral capture time up to 1 ms per point. This system has proven to be highly efficient for the XRF mapping of elements in large biological samples, achieving comparables results to those obtained by SR-µXRF. Thus, images of As and Cu accumulation in renal cortex of arsenic-exposed rats were obtained by both methodologies. However, the new imaging system enables the XRF scanning in few minutes, whereas SR-µXRF required several hours. These and other advantages as well as the potential applications of this system, will be discussed.

Palabras llave : XRF-Imaging; biological samples; multi-elemental mapping.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons