SciELO - Scientific Electronic Library Online

 
vol.89 número2Experiencia inicial en México con la prótesis aórtica transcatéter Evolut R por abordaje aórtico directoEvaluación del efecto de las hospitalizaciones sobre mortalidad en pacientes con Insuficiencia cardíaca seguidos en atención primaria índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Archivos de cardiología de México

versión On-line ISSN 1665-1731versión impresa ISSN 1405-9940

Resumen

NAVARRO-GUZMAN, Eduardo A. et al. Correlation of perfusion index with patent ductus arteriosus repercussion in premature newborns. Arch. Cardiol. Méx. [online]. 2019, vol.89, n.2, pp.123-129.  Epub 09-Dic-2020. ISSN 1665-1731.  https://doi.org/10.24875/acm.m19000021.

Background:

The ductus arteriosus is a necessary structure in fetal circulation, and its patency can produce hemodynamic alterations. The diagnostic gold standard is echocardiography, not always available. In the neonatal intensive care unit (NICU) they have pulse oximetry that measures perfusion index (PI), which could be used as a diagnostic tool in hemodynamic significant patent ductus arteriosus (HSPDA).

Objective:

To correlate the perfusion index increment (ΔPI) in 24 and 72 h after birth with HSPDA in premature newborns of NICU in a second level hospital.

Materials and methods:

This is an analytic prospective study which included neonates of 26-34 weeks of gestational age, without comorbidities, who underwent echocardiography and measurement of PI in arm and leg, 24 and 72 h after birth. We did bivariate analysis with Y2/exact Fisher test and Student t-test/Mann-Whitney U test, besides Spearman correlation and linear regression for value prediction.

Results:

We included 39 premature newborns. We did not find significant differences between patients without and with HSPDA (Median: 0.22 [0.06-0.58] vs. 0.03 [–0.27-0.2]; p = 0.09) at 24 h neither 72 h after birth (Median: 0.2 [0-0.47] vs. 0.45 [–0.37-0.76]; p = 0.47). We found a positive correlation between ductus arteriosus diameter (DAD) and ΔPI (r: 0.78; CI 95%: 0.6-0.88; p = 0.01). The prediction formula with linear regression is expressed this way: DAD = 1.31 + (2.05 x ΔIP).

Conclusions:

The PI doesn´t allow us to discriminate between patient without and with HSPDA. The ΔPI could be a tool for the monitorization of DAD in neonates 72 h after birth.

Palabras llave : Patent ductus arteriosus; Echocardiography; Infant; Newborn; Perfusion index; Mexico.