SciELO - Scientific Electronic Library Online

 
vol.81 número2Algunas características socioeconómicas de pacientes con infarto agudo del miocardio del Instituto Nacional de Cardiología Ignacio Chávez. Comparación de dos decenios: 1954-1964 y 1997-2007El poder del ventrículo derecho y del izquierdo: son parámetros hemodinámicos que correlacionan con la posibilidad de ser respondedor durante el reto agudo con vasodilatadores en la hipertensión arterial pulmonar idiopática índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Archivos de cardiología de México

versión On-line ISSN 1665-1731versión impresa ISSN 1405-9940

Resumen

GUEVARA-VALDIVIA, Milton E. et al. Remote monitoring and follow up of implantable cardioverter defibrillators and cardiac resynchronization therapy devices. Arch. Cardiol. Méx. [online]. 2011, vol.81, n.2, pp.93-99. ISSN 1665-1731.

Introduction: The implantable cardiac devices like regular pacemaker, cardiac resynchronization therapy (CRT) automatic implantable defibrillators (ICD) and CRT associate with ICD (CRT-D) are now being used frequently. Patient visits to pacemaker and ICD clinics for review and monitoring, has increases significantly. We present the experience of monitoring via satellite of patients with implantable cardiac devices in Mexico. Methods: Eighteen patients were selected from the arrhythmia Service Cardiac Electrophysiology and Stimulation of High Specialty Medical Unit (UMAE) of Specialties Hospital Dr. Antonio Fraga Mouret. National Medical Center (NMC) La Raza Mexican Social Security Institute (IMSS), who had a device (CRT, ICD y CRT-D) that is able to send information through the BIOTRONIK Home Monitoring system, from March 2006, to March 2009. Results: We obtained 4,980 transmissions as reports and 149 alerts recorded events, of which 50 were in ventricular fibrillation, 14 in ventricular tachycardia, frequent ventricular extra systoles exceeded by the range allowed in one hour were 25, electrograms default 26; and atrial fibrillation at 11. Conclusions: The monitoring system via satellite is reliable and useful diagnostic tool, which permits early detection, opportune treatment and effective monitoring of implantable cardiac devices.

Palabras llave : Home Monitoring; Follow-up; Arrhythmias; Cardiac Resynchronization Therapy; Automatic implantable defibrillator; Mexico.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons